| 1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677787980 |
- Kernel driver acbel-fsg032
- ==========================
- Supported chips:
- * ACBEL FSG032-00xG power supply.
- Author: Lakshmi Yadlapati <lakshmiy@us.ibm.com>
- Description
- -----------
- This driver supports ACBEL FSG032-00xG Power Supply. This driver
- is a client to the core PMBus driver.
- Usage Notes
- -----------
- This driver does not auto-detect devices. You will have to instantiate the
- devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for
- details.
- Sysfs entries
- -------------
- The following attributes are supported:
- ======================= ======================================================
- curr1_crit Critical maximum current.
- curr1_crit_alarm Input current critical alarm.
- curr1_input Measured output current.
- curr1_label "iin"
- curr1_max Maximum input current.
- curr1_max_alarm Maximum input current high alarm.
- curr1_rated_max Maximum rated input current.
- curr2_crit Critical maximum current.
- curr2_crit_alarm Output current critical alarm.
- curr2_input Measured output current.
- curr2_label "iout1"
- curr2_max Maximum output current.
- curr2_max_alarm Output current high alarm.
- curr2_rated_max Maximum rated output current.
- fan1_alarm Fan 1 warning.
- fan1_fault Fan 1 fault.
- fan1_input Fan 1 speed in RPM.
- fan1_target Set fan speed reference.
- in1_alarm Input voltage under-voltage alarm.
- in1_input Measured input voltage.
- in1_label "vin"
- in1_rated_max Maximum rated input voltage.
- in1_rated_min Minimum rated input voltage.
- in2_crit Critical maximum output voltage.
- in2_crit_alarm Output voltage critical high alarm.
- in2_input Measured output voltage.
- in2_label "vout1"
- in2_lcrit Critical minimum output voltage.
- in2_lcrit_alarm Output voltage critical low alarm.
- in2_rated_max Maximum rated output voltage.
- in2_rated_min Minimum rated output voltage.
- power1_alarm Input fault or alarm.
- power1_input Measured input power.
- power1_label "pin"
- power1_max Input power limit.
- power1_rated_max Maximum rated input power.
- power2_crit Critical output power limit.
- power2_crit_alarm Output power crit alarm limit exceeded.
- power2_input Measured output power.
- power2_label "pout"
- power2_max Output power limit.
- power2_max_alarm Output power high alarm.
- power2_rated_max Maximum rated output power.
- temp[1-3]_input Measured temperature.
- temp[1-2]_max Maximum temperature.
- temp[1-3]_rated_max Temperature high alarm.
- ======================= ======================================================
|