adp1050.rst 1.8 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364
  1. .. SPDX-License-Identifier: GPL-2.0
  2. Kernel driver adp1050
  3. =====================
  4. Supported chips:
  5. * Analog Devices ADP1050
  6. Prefix: 'adp1050'
  7. Addresses scanned: I2C 0x70 - 0x77
  8. Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/ADP1050.pdf
  9. Authors:
  10. - Radu Sabau <radu.sabau@analog.com>
  11. Description
  12. -----------
  13. This driver supprts hardware monitoring for Analog Devices ADP1050 Digital
  14. Controller for Isolated Power Supply with PMBus interface.
  15. The ADP1050 is an advanced digital controller with a PMBus™
  16. interface targeting high density, high efficiency dc-to-dc power
  17. conversion used to monitor system temperatures, voltages and currents.
  18. Through the PMBus interface, the device can monitor input/output voltages,
  19. input current and temperature.
  20. Usage Notes
  21. -----------
  22. This driver does not auto-detect devices. You will have to instantiate
  23. the devices explicitly.
  24. Please see Documentation/i2c/instantiating-devices.rst for details.
  25. Platform data support
  26. ---------------------
  27. The driver supports standard PMBus driver platform data.
  28. Sysfs Attributes
  29. ----------------
  30. ================= ========================================
  31. in1_label "vin"
  32. in1_input Measured input voltage
  33. in1_alarm Input voltage alarm
  34. in2_label "vout1"
  35. in2_input Measured output voltage
  36. in2_crit Critical maximum output voltage
  37. in2_crit_alarm Output voltage high alarm
  38. in2_lcrit Critical minimum output voltage
  39. in2_lcrit_alarm Output voltage critical low alarm
  40. curr1_label "iin"
  41. curr1_input Measured input current.
  42. curr1_alarm Input current alarm
  43. temp1_input Measured temperature
  44. temp1_crit Critical high temperature
  45. temp1_crit_alarm Chip temperature critical high alarm