actions,owl-timer.txt 746 B

123456789101112131415161718192021
  1. Actions Semi Owl Timer
  2. Required properties:
  3. - compatible : "actions,s500-timer" for S500
  4. "actions,s700-timer" for S700
  5. "actions,s900-timer" for S900
  6. - reg : Offset and length of the register set for the device.
  7. - interrupts : Should contain the interrupts.
  8. - interrupt-names : Valid names are: "2hz0", "2hz1",
  9. "timer0", "timer1", "timer2", "timer3"
  10. See ../resource-names.txt
  11. Example:
  12. timer@b0168000 {
  13. compatible = "actions,s500-timer";
  14. reg = <0xb0168000 0x100>;
  15. interrupts = <GIC_SPI 10 IRQ_TYPE_LEVEL_HIGH>,
  16. <GIC_SPI 11 IRQ_TYPE_LEVEL_HIGH>;
  17. interrupt-names = "timer0", "timer1";
  18. };